[probable_causes]

What we typically find

  • No or low water circulation
  • Failed non-return valve mixing cold water back
  • Low refrigerant charge
  • Faulty water temperature probe or controller setting
  • Undersized or uninsulated pipework
[diagnostic_protocol]

How we isolate the fault

  • Verify inlet and outlet water temperature rise across the condenser
  • Confirm water flow rate — most 'not heating' calls are actually flow or circulation faults
  • Check high and low pressure switch operation and refrigerant charge
  • Test the defrost cycle, four-way valve and evaporator fan operation
  • Inspect the controller, temperature probes and element back-up wiring
  • Check the geyser, thermostat, non-return valves and pipe insulation